EM America

  • Increase font size
  • Default font size
  • Decrease font size
Home Wastewater Treatment

EM-1® Waste Treatment for Wastewater

E-mail Print PDF
Water Treatment with Effective Microorganisms
  • Eliminate Odors
  • Increase Plant Capacity
  • Decreases Costs of Treatment
  • More Easily Meet NPDES Requirements
  • EM America provides clients with specifically-targeted applications of EM Technology® that are able to dramatically change the wastewater treatment process while making no changes to the current equimpement. Timing, flow rates, system design, and management are all considered in developing an application program for a wastewater treatment plant and collection system (sewer).

    Since every treatment system is in itself a separate ecosystem, EM America will custom-design each application for a wastewater treatment system after an assessment of the entire system.

    How It Works

    EM•1® Waste Treatment has a unique ability to stabilize complex proteins through a shift from anaerobic putrefaction cycles to a fermentative cycle. Hair and plastics can play havoc with the balancing of an anaerobic digester by creating over-thickening of the scum layer. Hair is primarily composed of complex proteins, which have been historically difficult to stabilize to a point at which the biological breakdown will occur in a timely manner. EM•1® Waste Treatment will assist by accelerating protein stabilization.

    The microbes in EM•1® Waste Treatment secrete beneficial substances such as organic acids, enzymes and antioxidants (chelated minerals and vitamins) when in contact with organic matter. In wastewater applications, EM•1® assists in shifting conditions from putrefactive to non-putrefactive. This unique ability enables EM•1® to transition the wastewater collection system into a pretreatment system, thereby lowering the loading demand on wastewater treatment plants. Essentially, consistent applications of EM Technology® into the collection system will increase the capacity of the treatment plant, decrease the operation costs, and improve the efficiency of the entire system.

    Applications

    EM•1® Waste Treatment is applied at various stages in the treatment process for optimum results. The application site and dosage amounts are dependent on the type of treatment system, the age of the system, and the goals of the parties involved. Application rates can vary from 1: 1000 to 1: 40,000. The average rate into a treatment system is around 1: 10,000 (based on daily flow). The EM•1® is activated and injected at various points throughout the collection system on a steady flow.

    Wastewater Injection System

    The average daily flow is determined. After a site assessment and preliminary data is collected for at least one year that proper amount of product is calculated. Activated EM•1® is injected at a rate of !:10,000 on a daily basis in the collection system as far away from the plant as possible to increase residence time in the line.

    A siphon/venture unit can be installed to work on a pressurized trigger or an injection pump can be installed on site. For economical purposes on large systems, we generally do all applications with an Activated version of EM•1®.

    In systems that have high flow rates or excessive sludge levels, the addition of EM•1® Bokashi can accelerate sludge digestion.

    alt

    For Odor control, a fogging system will be installed in lift stations, at the headworks, or other areas of concern.






    MSDS

    EM•1® Waste Treatment

    PREPARED: 09/01/06

    PRODUCT NAME: EM•1® Waste Treatment

    PRODUCED BY:
    EMRO USA, Inc. dba EMRO USA Effective Microorganisms
    2440 N. Coyote Drive Suite 126
    Tucson, AZ 85745
    Phone: (520) 792-3143 Fax: (928) 563-1037>

    SECTION I - PRODUCT IDENTIFICATION
    GENERAL OR GENERIC NAME: Liquid Microbial Waste Treatment
    HAZARD RATING:
    HEALTH - 0 Normal Material
    FIRE - 0 Will not burn
    REACTIVITY - 0 Stable

    SECTION II - HAZARDOUS INGREDIENTS
    If present, carcinogens and chemicals subject to reporting are identified in this section:

    INGREDIENTS %(By Volume) Note

    No hazardous ingredients present; not hazardous to humans, animals or plants.

    SECTION III - PHYSICAL DATA
    BOILING POINT: >100 °C
    SPECIFIC GRAVITY: 1.2 (25°c)
    VAPOR PRESSURE: N/D
    SOLUBILITY IN WATER: Complete
    VAPOR DENSITY: Air = 1
    MELTING POINT: N/A
    % VOLATILE BY VOLUME: 0
    EVAPORATION RATE: Equal to water
    APPERANCE AND ODOR: Brown liquid; mild
    pH OF SOLUTION: 3.5

    SECTION IV - FIRE AND EXPLOSION INFORMATION
    FLASH POINT: N/A
    EXPLOSION LIMIT: 0
    EXTINGUISHING: N/A
    FIRE FIGHTING PROCEDURES: N/A
    SPECIAL FIRE & EXPLOSION HAZARDS: None
    HAZARDOUS DECOMPOSITION BYPRODUCTS: None

    SECTION V - HEALTH HAZARD DATA
    HEALTH HAZARDS: None
    CARCINOGENICITY: Non-carcinogenic
    EFFECTS OF CHRONIC OVEREXPOSURE: None
    PERMISSIBLE EXPOSURE LEVEL: None; see Section II
    PRIMARY ROUTES OF ENTRY: Skin contact, Eye contact, Ingestion, Inhalation
    SIGNS AND SYMPTOMS OF EXPOSURE:
    SKIN - None
    EYES - May cause eye irritation
    INHALATION - None
    INGESTION - May cause gas

    FIRST AID:
    IF ON SKIN - None
    IF ON EYES - Flush with fresh water
    IF INHALED - None
    IF INGESTED - Drink fresh water

    SECTION VI - REACTIVITY DATA
    INCOMPATIBILITY: None
    HAZARDOUS POLYMERIZATION: Will not occur
    HAZARDOUS DECOMPOSITION OR BYPRODUCTS: None; biodegradable
    STABILITY: Stable, not effected by freezing. No toxic fumes.

    SECTION VII - SPILL OR LEAK PROCEDURES
    IN CASE OF LEAK OR SPILL: Mop up with fresh water, sewer disposal
    WASTE DISPOSAL METHOD: Sewer disposal
    HANDLING AND STORING PRECAUTIONS: Store at room temperature
    OTHER PRECAUTIONS: Not recommended for human consumption

    SECTION VIII - PROTECTIVE EQUIPMENT TO BE USED
    RESPIRATORY PROTECTION: None
    VENTILATION: None
    PROTECTIVE GLOVES: Optional
    EYE PROTECTION: Safety glasses recommended
    PROTECTIVE CLOTHING: None
    WORK PRACTICES: Clean up spills immediately; floor will be slick