Biosolids is a nice sounding word for sludge. Sludge from a treatment plant is pretty ripe, releasing all sorts of volatile organic compounds(VOC) that give it a characteristic smell. High BOD, COD, Fats Oils & Greases (FOGs) produce hydrogen sulfide (H2S) and ammonia NH3. The use of Dr. Higa's Effective Microorganisms™ will rid any biosolids handling facility of its odor problem.
Odors can be controlled by misting or fogging the area and by incorporating EM•1® into the materials while still in solids handling. In areas where the biosolids are being collected, fogging the area will prevent corrosion on equipment from the sulfuric acid produced by the H2S and will make for a safer working environment.
Digestion rates in the composting process can also be noted by incorporating early on in the system as a pre-treatment. Rates are suggested below.
Management of biosolids varies. Sometimes the solids are composted and used as fertilizers. Other times they are incinerated or injected into the ground. No matter what is done, they all have odor issues.
- The equipment can be treated with a 50:1 application rate to clean and eliminate odor.
- The facility can be fogged on a regular basis with a 100:1 application.
Activated EM•1® is generally used for these applications. Application rates for EM•1® and Activated EM•1® are the same. Activation is strictly a function of economics as it results in 22
How It Works
EM•1® Waste Treatment has a unique ability to stabilize complex proteins through a shift from anaerobic putrefaction cycles to a fermentative cycle. Hair and plastics can play havoc with the balancing of an anaerobic digester by creating over-thickening of the scum layer. Hair is primarily composed of complex proteins, which have been historically difficult to stabilize to a point at which the biological breakdown will occur in a timely manner. EM•1® Waste Treatment will assist by accelerating protein stabilization.The microbes in EM•1® Waste Treatment secrete beneficial substances such as organic acids, enzymes and antioxidants (chelated minerals and vitamins) when in contact with organic matter. In wastewater applications, EM•1® assists in shifting conditions from putrefactive to non-putrefactive. This will improve the overall microbial cultures in the biosolids and speed up the finishing time of the materials with little change in methods and no change in equipment used.
Applications
EM•1® Waste Treatment is applied at various stages in the treatment process for optimum results. The application site and dosage amounts are dependent on the condition of the material to be treated. If it is odorous and putrefied, it will require a higher rate of application. Typical application rates to biosolids are 1.5-2 gallons per ton at time of mixture. From the application, conventional processing steps are followed thereafter.MSDS
EM•1® Waste TreatmentPREPARED: 09/01/06
PRODUCT NAME: EM•1® Waste Treatment
PRODUCED BY:
EMRO USA, Inc. dba EMRO USA Effective Microorganisms
2440 N. Coyote Drive Suite 126
Tucson, AZ 85745
Phone: (520) 792-3143 Fax: (928) 563-1037>
SECTION I - PRODUCT IDENTIFICATION
GENERAL OR GENERIC NAME: Liquid Microbial Waste Treatment
HAZARD RATING:
HEALTH - 0 Normal Material
FIRE - 0 Will not burn
REACTIVITY - 0 Stable
SECTION II - HAZARDOUS INGREDIENTS
If present, carcinogens and chemicals subject to reporting are identified in this section:
INGREDIENTS %(By Volume) Note
No hazardous ingredients present; not hazardous to humans, animals or plants.
SECTION III - PHYSICAL DATA
BOILING POINT: >100 °C
SPECIFIC GRAVITY: 1.2 (25°c)
VAPOR PRESSURE: N/D
SOLUBILITY IN WATER: Complete
VAPOR DENSITY: Air = 1
MELTING POINT: N/A
% VOLATILE BY VOLUME: 0
EVAPORATION RATE: Equal to water
APPERANCE AND ODOR: Brown liquid; mild
pH OF SOLUTION: 3.5
SECTION IV - FIRE AND EXPLOSION INFORMATION
FLASH POINT: N/A
EXPLOSION LIMIT: 0
EXTINGUISHING: N/A
FIRE FIGHTING PROCEDURES: N/A
SPECIAL FIRE & EXPLOSION HAZARDS: None
HAZARDOUS DECOMPOSITION BYPRODUCTS: None
SECTION V - HEALTH HAZARD DATA
HEALTH HAZARDS: None
CARCINOGENICITY: Non-carcinogenic
EFFECTS OF CHRONIC OVEREXPOSURE: None
PERMISSIBLE EXPOSURE LEVEL: None; see Section II
PRIMARY ROUTES OF ENTRY: Skin contact, Eye contact, Ingestion, Inhalation
SIGNS AND SYMPTOMS OF EXPOSURE:
SKIN - None
EYES - May cause eye irritation
INHALATION - None
INGESTION - May cause gas
FIRST AID:
IF ON SKIN - None
IF ON EYES - Flush with fresh water
IF INHALED - None
IF INGESTED - Drink fresh water
SECTION VI - REACTIVITY DATA
INCOMPATIBILITY: None
HAZARDOUS POLYMERIZATION: Will not occur
HAZARDOUS DECOMPOSITION OR BYPRODUCTS: None; biodegradable
STABILITY: Stable, not effected by freezing. No toxic fumes.
SECTION VII - SPILL OR LEAK PROCEDURES
IN CASE OF LEAK OR SPILL: Mop up with fresh water, sewer disposal
WASTE DISPOSAL METHOD: Sewer disposal
HANDLING AND STORING PRECAUTIONS: Store at room temperature
OTHER PRECAUTIONS: Not recommended for human consumption
SECTION VIII - PROTECTIVE EQUIPMENT TO BE USED
RESPIRATORY PROTECTION: None
VENTILATION: None
PROTECTIVE GLOVES: Optional
EYE PROTECTION: Safety glasses recommended
PROTECTIVE CLOTHING: None
WORK PRACTICES: Clean up spills immediately; floor will be slick
Buy Now
EM•1® Microbial Inoculant. 12oz recyclable bottle only $14.99.
EM•1® Septic Treatment 1 liter Only $22.99.
EM•1® Microbial Inoculant. 32oz recyclable bottle only $22.99.
EM•1® Microbial Inoculant. 1 Gal recyclable bottle only $57.99.
EM•1® Waste Treatment 5-gallon Container. Only $249.99.
EM•1® Bokashi Packets. 12 for only $19.99.
EM•1® Bokashi 18lbs. Only $79.75.